13
IGP-RAPID®primer 134SA-A1
Highly reactive primer that optimally prepares MDF substrates for finishing with IGP-RAPID®top.
download PDFCharacteristics
- Silk gloss
- Var. fine texture
- Indoor quality
Powder properties
Particle size:
< 100 μm
Solids:
> 99 %
Density:
1.2 kg/l-1.6 kg/l
Suitability for storage:
min.
6
months
at ≤
15 °C
min.
6
months
at ≤
15 °C
in an unopened original container
Color tones:
ca. RAL 7035
Film properties
Tested on
Substrate:
EGGER MBP-L 25mm
Tested setting:
Tested with 381M with a total film thickness > 160μm
Object temperature:
135 °C, 5 min.
Mechanical tests
Hinge Hole Test
≤ 1.1
IGP AA341.54
Chemical tests
Acetone test
2N Level 2
IGP AA341.58
Processing
Pre-treatment
If the surface finish of the MDF ex-works does not meet the quality requiremens of the end product, the surface has to be sanded. This will ensure that the material has an evenly smooth surface and is free of any contaminants, minor scratches, dust, grease, etc. For more information, see IGP-TI 111.
Coating devices
All conventional electrostatic systems with corona charging.
For the construction and operation of powder coating plants, the following regulations must be complied with: ATEX RL 2014/34/EU, EN 50177, DIN EN 16985.
For the construction and operation of powder coating plants, the following regulations must be complied with: ATEX RL 2014/34/EU, EN 50177, DIN EN 16985.
Curing conditions
TObject | t min | t max |
---|---|---|
125 °C | 10 minutes | 15 minutes |
135 °C | 5 minutes | 10 minutes |
150 °C | 3 minutes | 5 minutes |
Due to the limited thermal conductivity, the use of infrared- (electric / gas catalytic) or convectional - infrared combined ovens is recommended.
In order to determine ideal curing conditions, we recommend practical trials with the respective object and curing oven.
The curing conditions must be carefully controlled. Powder coatings cured outside the curing window may show deficiencies in the film flexibility. Our technical customer service will advise you.
In order to determine ideal curing conditions, we recommend practical trials with the respective object and curing oven.
The curing conditions must be carefully controlled. Powder coatings cured outside the curing window may show deficiencies in the film flexibility. Our technical customer service will advise you.
Reclaimability
Small portions of recycled powder can be added, automatically if possible, to the fresh powder. Important: Keep overspray to an absolute minimum.
Further information
Packaging
20 kg cardboard box with inserted antistatic PE liner
Paint removal and disposal
After use, coated goods should be supplied to the normal recycling process. The disposal methods for sludges or residual powders must be observed in accordance with the local official provisions whilst taking Waste Code “080201 Coating Powder Wastes” in accordance with the European Waste Catalogue into consideration.
This application-related advice is given to the best of our knowledge. However, this information is non-obligatory and does not exempt you from carrying out your own tests. Application, use and processing of these products are beyond our control and are therefore on your responsibility. Consult the Safety Data Sheet prior to use.